EasyManua.ls Logo

Toro Multi Pro 5800-G - Performing a Catch Test

Toro Multi Pro 5800-G
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
g192607
Figure45
1.Section-bypassshutoffvalve(closedposition)
5.Formachinesoperatedintheapplication-rate
mode,ensurethatthesection-bypassshutoff
valveisclosed(Figure45).
6.Engagetheparkingbrakeandstarttheengine.
Note:Allowtheenginetowarmfor10minutes.
7.Formachinesoperatedintheapplication-rate
mode,performthestepsinUsingtheT est
Speed;refertotheSoftwareGuideforthe
MultiPro5800-Dand5800-Gturfsprayerswith
ExcelaRatespraysystem.
Note:Setthesimulatedtestspeedbetween4
km/h(2mph)and14km/h(9mph).
PerformingaCatchTest
1.Setthespraysectionswitch(es)totheON
positionforthesection(s)thatyouaretesting.
2.SetthethrottletotheFASTposition.
3.SetthemastersectionswitchtotheONposition.
4.Performa15-secondcatchtestat1oftheactive
spraynozzles.
g193177
Figure46
5.Shutoffthemastersectionswitch,setthe
throttletotheslowposition,shutoffthespray
pump,andshutofftheengine.
6.Setthegraduatedcontaineronalevelsurface
andnotetheuidvolume(Figure47).
Important:Whenyouarereadingthe
graduatedcontainer,youmustsetthe
containeronalevelsurface.
Important:Whenyouarereadingthe
graduatedcontainer,readtheuidvolumein
thegraduatedcontaineratthelowestpoint
oftheuid-surfacecurve.
Important:Smallerrorsreadingtheuid
volumeinthegraduatedcontainerwill
signicantlyimpacttheaccuracyofthe
sprayercalibration.
g193829
Figure47
1.Highestpointofthe
uid-surfacecurve(donot
measurehere)
3.Levelsurface
2.Lowestpointofthe
uid-surfacecurve
(measurehere)
7.Comparethevolumeofwaterinthegraduated
containerwiththenozzlevolumeinthe
15-secondcatchtesttable.
15-SecondCatchTestTable
NozzleColor
Milliliters
collectedin15
seconds
Ouncescollected
in15seconds
Yellow1896.4
Red37812.8
Brown47316.0
Gray
56719.2
White
757
25.6
38

Table of Contents