EasyManua.ls Logo

Toro Multi Pro 5800-G - Catch Test; Preparing for the Catch Test

Toro Multi Pro 5800-G
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
g195516
Figure43
1.Manualmodeposition
2.Sprayer-modeswitch
3.SetthemastersectionswitchtotheOFF
position;refertoFigure41inSprayinginthe
ApplicationRateMode(page35).
4.Adjustthethrottletothedesiredenginespeed
tospray;refertoFigure42inSprayinginthe
ApplicationRateMode(page35).
5.Drivetothesprayinglocation.
6.Lowerthesectionsintoposition.
7.Settheindividualsectionswitches,asneeded,
totheONposition;refertoFigure41inSpraying
intheApplicationRateMode(page35).
8.Usetheapplication-rateswitchtoachievethe
desiredspraypressureasindicatedinthe
nozzle-selectionguideprovidedwiththesprayer
(Figure44).
g195528
Figure44
1.Application-rateswitch
9.Driveatthedesiredspeedandthensetthe
mastersectionswitchtotheONpositiontobegin
spraying;refertoFigure41inSprayinginthe
ApplicationRateMode(page35).
Note:Whenthetankisnearlyempty,the
agitationmaycausefoaminginthetank.In
thiscase,turntheagitationswitchtotheOFF
position.Alternatively,youcanaddanti-foaming
agenttothetank.
10.Whenyouarenishedspraying,setthemaster
sectionswitchtotheOFFpositiontoturnoffall
sections,thensetthespray-pumpswitchtothe
OFFposition.
Note:Returnthesectionstothetransport
positionanddrivethesprayertothecleaning
area.
Important:Alwaysraisethesections
untiltheyhavemovedcompletelyinto
section-transportcradleformingthe“X”
transportpositionandthesectioncylinders
arefullyretractedwheneveryoumovethe
sprayerfrom1sprayingareatoanother,or
movetoastorageorcleaningarea.
CatchTest
Customerprovidedequipment:Agraduated
catchcontainer(acontainerwith0.01ml(1/2.oz)
incrementsispreferred)andstopwatch.
PreparingfortheCatchTest
Important:Wheneverpossible,donotuse
reclaimedwater(graywater)inthespraytank.
1.Ensurethatthesprayertankisclean;referto
CleaningtheSprayerSystem(page41).
2.Fillthesprayertankwithatleast568L(150US
gallons)offreshwater;refertoFillingtheSpray
Tank(page27).
3.Ensurethatthenozzlesthatyouintendtotest
areintheactivespray(down)position.
4.Formachinesoperatedintheapplication-rate
mode,ensurethattheknobforthe
section-bypassshutoffvalveisintheclosed
position(Figure45).
37