Toro Multi Pro 5800-G - Catch Test; Preparing for the Catch Test

Toro Multi Pro 5800-G
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
g195516
Figure43
1.Manualmodeposition
2.Sprayer-modeswitch
3.SetthemastersectionswitchtotheOFF
position;refertoFigure41inSprayinginthe
ApplicationRateMode(page35).
4.Adjustthethrottletothedesiredenginespeed
tospray;refertoFigure42inSprayinginthe
ApplicationRateMode(page35).
5.Drivetothesprayinglocation.
6.Lowerthesectionsintoposition.
7.Settheindividualsectionswitches,asneeded,
totheONposition;refertoFigure41inSpraying
intheApplicationRateMode(page35).
8.Usetheapplication-rateswitchtoachievethe
desiredspraypressureasindicatedinthe
nozzle-selectionguideprovidedwiththesprayer
(Figure44).
g195528
Figure44
1.Application-rateswitch
9.Driveatthedesiredspeedandthensetthe
mastersectionswitchtotheONpositiontobegin
spraying;refertoFigure41inSprayinginthe
ApplicationRateMode(page35).
Note:Whenthetankisnearlyempty,the
agitationmaycausefoaminginthetank.In
thiscase,turntheagitationswitchtotheOFF
position.Alternatively,youcanaddanti-foaming
agenttothetank.
10.Whenyouarenishedspraying,setthemaster
sectionswitchtotheOFFpositiontoturnoffall
sections,thensetthespray-pumpswitchtothe
OFFposition.
Note:Returnthesectionstothetransport
positionanddrivethesprayertothecleaning
area.
Important:Alwaysraisethesections
untiltheyhavemovedcompletelyinto
section-transportcradleformingthe“X”
transportpositionandthesectioncylinders
arefullyretractedwheneveryoumovethe
sprayerfrom1sprayingareatoanother,or
movetoastorageorcleaningarea.
CatchTest
Customerprovidedequipment:Agraduated
catchcontainer(acontainerwith0.01ml(1/2.oz)
incrementsispreferred)andstopwatch.
PreparingfortheCatchTest
Important:Wheneverpossible,donotuse
reclaimedwater(graywater)inthespraytank.
1.Ensurethatthesprayertankisclean;referto
CleaningtheSprayerSystem(page41).
2.Fillthesprayertankwithatleast568L(150US
gallons)offreshwater;refertoFillingtheSpray
Tank(page27).
3.Ensurethatthenozzlesthatyouintendtotest
areintheactivespray(down)position.
4.Formachinesoperatedintheapplication-rate
mode,ensurethattheknobforthe
section-bypassshutoffvalveisintheclosed
position(Figure45).
37