Reelmaster 5010- H Page 5 - 23 Electrical System
Fault Code
Fault Description Service Suggestions
43 CAN- bus fault for motor/generator Check CAN- bus connection to
motor/generator
Verify battery power exists at motor/generator
Check CAN- bus termination resistors
44 CAN- bus fault for InfoCenter Check CAN- bus connection to InfoCenter
Display
Verify battery power exists at InfoCenter
Display
Check CAN- bus termination resistors
45 Software version incompatible with #1 cutting
reel motor
Contact Toro d istributor to update software
46 Software version incompatible with #2 cutting
reel motor
Contact Toro d istributor to update software
47 Software version incompatible with #3 cutting
reel motor
Contact Toro d istributor to update software
48 Software version incompatible with #4 cutting
reel motor
Contact Toro d istributor to update software
49 Software version incompatible with #5 cutting
reel motor
Contact Toro d istributor to update software
50 Software version incompatible with
motor/generator
Contact Toro d istributor to update software
51 Software version incompatible with InfoCenter Contact Toro d istributor to update software
52 Software version incompatible within entire
system
Contact Toro d istributor to update software
53 TEC output current for hydraulic solenoid coil
SV1 is excessive
Check lift manifold solenoid coil SV1 and cir-
cuit wiring
54 TEC output current for hydraulic solenoid coil
SV2 is excessive
Check lift manifold solenoid coil SV2 and cir-
cuit wiring
55 TEC output current for hydraulic solenoid coil
SV3 is excessive
Check lift manifold solenoid coil SV3 and cir-
cuit wiring
56 TEC output current for hydraulic solenoid coil
SVRV is excessive
Check lift manifold solenoid coil SVRV and cir-
cuit wiring
57 Cutting unit motor sizes (5” and 7”) are mixed Check that all 5 cutting unit motors are for the
same size cutting unit on the machine
58 Current sensor fault in motor/generator
controller
Motor/generator controller is faulty if this fault
continues to occur (generator motor should
be OK)
59 Line contactor - open fault Check main contactor and circuit wiring
Replace main contactor if faulty
60 Line contactor - closed fault Check main contactor and circuit wiring
Replace main contactor if faulty
61 Line contactor - over current Motor/generator is faulty if this fault continues
to occur
62 Fault latch - phase OC Motor/generator is faulty if this fault continues
to occur