Reelmaster 5010- H Page 5 - 59 Electrical System
5. Connect multimeter (ohms setting) leads to relay ter-
minals 30 and 87. Ground terminal 86 and apply +12
VDC to terminal 85. The relay should have continuity be-
tween terminals 30 and 87 as +12 VDC is applied to ter-
minal 85. The relay should not have continuity between
terminals 30 and 87 as +12 VDC is removed from termi-
nal 85.
6. When relay testing is complete, disconnect voltage
and multimeter leads from the relay terminals.
7. Replace relay if testing d etermines that it is faulty.
8. Secure relay to machine and connect machine wire
harness connector to relay. Install hood saddle to ma-
chine if it was removed. Lower and secure hood.