Reelmaster 5010- H Page 5 - 63 Electrical System
Because of the solid state circuitry built into the TEC
controller, there is no method to test it directly. The TEC
may be damaged if an attempt is made to test it with an
electrical test device, such as a digital multimeter.
IMPORTANT: Before performing welding on the ma-
chine, disconnect both positive and negative bat-
tery cables from the battery, disconnect both w ire
harness connecto rs from the TEC controller and
disconnect the terminal connector from the alterna-
tor to prevent damage to the electrical system.
Figure 59
WIRE HARNESS CONNECTOR FOR
TEC CONTROLLER
11
1
21
31
41
10
50
40
30
20
POSITION
NOTE TAB
Electrical