Pre-Maintenance Procedures
Moving a Non-Functional Machine
IMPORTANT
Do not tow or pull the machine without first opening the bypass valves in this
procedure, or you will damage the hydraulic system.
Note: Opening the bypass valves will ease moving the machine, but the tracks may still skid
due to their length and resistance.
1. If possible, raise the hopper and install the cylinder lock.
2. Shut off the engine and remove the key.
3. Using a wrench, turn the bypass valve on the left and right transaxles so that the flat
sides of the valve face left and right (Tow position
).
g375754
4. Tow the machine as required.
5. After repairing the machine, turn the bypass valves so that the flat sides face up and
down (drive position
).
6. Remove the cylinder lock and lower the hopper.
Maintenance: Pre-Maintenance Procedures Page 5–3 3462-915 A