Workman GTX Electric Lithium Page 3B -- 23 Electrical System
Problem Corrective ActionPossible Cause
Code E--0--2--4 Charger failed to initialize Disconnect the charger AC input
and battery connections for 30
seconds, then reconnect the
charger.
Code E--0--2--5 Low AC voltage oscillation error The charger requires an AC power
source that provides stable AC
power between 85 -- 270 VAC at
45--65 Hz. Confirm the AC power
supply capacity and verify AC input
cable gauge.
Code E--0--3--7 Re--programming failed Software upgrade failure or script
operation failure. Ensure that t he
new software is correct.
Code E--0--2--9, E--0--3--0,
E -- 0 -- 3 -- 2 , E -- 0 -- 4 -- 6 , o r E -- 0 -- 6 -- 0
Communication error with battery Ensure that the connection of the
signal wires to each battery is clean
and secure.
Battery Charger Fault Codes
Problem Possible Cause Corrective Action
Codes F--0--0--1, F--0--0--2,
F--0--0--3, F--0--0--4, F--0--0--5,
F--0--0--6, or F--0--0--7
Internal charger fault Remove the charger AC connection
and battery connection for a
minimum of 30 seconds, then
reconnect the charger.
The battery charger may require
replacement (contact an Authorized
Toro Distributor for assistance).