e-STUDIO205L/255/305/355/455 © 2009 TOSHIBA TEC CORPORATION All rights reserved
SELF-DIAGNOSIS MODES
2 - 182
9798 Network Temporary
communication
password setting
ALL - SYS Sets a temporary
communication
password.
The password can be
entered in
alphanumeric
characters (A to Z, a to
z, 0 to 9) up to 10 digits.
The entered password
is displayed with “*” on
the touch panel and the
self-diagnostic lists.
(Maximum 10 digits,
minimum 5 digits)
11
9799 General Local authentication
mode switchover
ALL 0
<0-1>
SYS Sets the authentication
mode when “0: (Internal
authentication)” is
selected in the code 08-
1471.
0: Card ID differs from
the User ID
1: Card ID is the same
as the User ID
1
9804 Image
processi
ng
Forcible mode change in
toner empty status
ALL 1
<0-2>
SYS 0: SLEEP MODE
1: AUTO POWER
SAVE
2: READY
1
9805 Laser Polygonal motor standby
rotation
Shift waiting time at job
end
ALL 3
<0-9>
SYS 0: 0 sec.
(current setting)
(Polygonal motor
ready rotation at job
end)
1 to 9:
Setting value x 5
sec.
1
9811-0 Finisher Stapling
setting
Maximum
number of
sheets
acceptable
exceeding
upper limit /
Long size
Plain/
Recycled
ALL 0
<-50-50>
SYS -50 to 50 4
9811-1 Thick1 ALL 0
<-50-50>
SYS 4
9811-2 Thick2 ALL 0
<-50-50>
SYS 4
9811-3 Thick3 ALL 0
<-50-50>
SYS 4
9814 General Number of
output pages
for pausing
continuous
printing for
2nd transfer
resistance
detection
control
At normal
temperat
ures
ALL 4
<0-100>
SYS When the setting value
of this code is “1” or
higher, the 2nd transfer
resistance detection is
performed every time
the number of pages of
(setting value X 100)
have output.
1
9815 General At low
temperat
ures
ALL 10
<0-100>
SYS When the setting value
of this code is “1” or
higher, the 2nd transfer
resistance detection is
performed every time
the number of pages of
(setting value X 10)
have output.
1
Setting mode (08)
Code
Classific
ation
Items
Functi
on
Default
<Acceptable
value>
Boa
rd
Contents
Proce
dure