2
© 2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455
SELF-DIAGNOSIS MODES
2 - 183
9819 General STAGE SSL ALL 1
<0-1>
SYS When remote scanning
is performed, the SSL
communication is
carried out.
0: Disabled
1: Enabled (SSL
communication)
1
9822 General STAGE SSL port
number
ALL 20443
<0-65535>
SYS When remote scanning
is performed using SSL
communication, the
SSL port number is set.
1
9825 Image Image quality of the
black part in the ACS
mode
ALL 0
<0-1>
SYS 0: Black
1: Gray scale
1
9826 General Disabling Media File
Save
ALL 0
<0-1>
SYS 0: Invalid
1: Valid
1
9828 General Remote scanning mode ALL 1
<0-1>
SYS 0: Batch
1: Sequential
1
9829 General Department
management limitation
setting
ALL 0
<0-1>
SYS Decide the default
limitation setting when
the new department
code is created.
0: No limit
1: Limited
1
9847 Finisher Hole punching setting ALL 0
<0-1>
SYS 0: Invalid
1: Valid
1
9880 General Total counter
transmission date setting
(2)
ALL 0
<0-31>
SYS 0 to 31 1
9881 General Day of total counter data
transmission
ALL 0
<0-127>
SYS 1 byte 00000000(0)-
01111111(127)
From the 2nd bit -
Sunday, Monday,
Tuesday, Wednesday,
Thursday, Friday,
Saturday
1
9882 Electroni
c filing
Display mode of the
used capacity on the e-
Filing administrator page
ALL 1
<0-1>
SYS 0: All files search
mode
1: Performance priority
mode
1
9883 General Hardcopy security
printing level 1
PPC 0
<0-1>
SYS Sets whether the
hardcopy security
printing is enabled or
disabled.
0: Disabled
1: Enabled
2
9884 Counter Count switching of
hardcopy security
printing level 1
PPC 0
<0-1>
SYS Sets the way of
counting for hardcopy
security printing
2
9886 Scanning Decimal point indication
for Enhanced Scan
Tem p la t e
SCN EUR: 0
Other: 1
<0-1>
SYS 0: Comma
1: Period
1
9888 Scanner Permission setting for
changing the scan
parameter when
recalling an extension
SCN 0
<0-1>
SYS 0: Prohibited
1: Permitted
1
9889 General Acceptance of data
cloning using USB
media
ALL 1
<0-1>
SYS Acceptance of the
usage of the USB data
cloning tool
0: Accepted
1: Not accepted
2
Setting mode (08)
Code
Classific
ation
Items
Functi
on
Default
<Acceptable
value>
Boa
rd
Contents
Proce
dure