e-STUDIO205L/255/305/355/455 © 2009 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 42
(4) Install the high-voltage transformer jig and fix
it with 2 screws.
Note:
Be careful not to let the connector and the
harness be caught.
Fig. 3-22
(5) Fix the green cable of the high-voltage
transformer jig to the frame of the equipment.
Fig. 3-23
(6) Install the door switch jig.
(7) Take off the transfer roller unit.
(8) Close the automatic duplexing unit.
Fig. 3-24
Process unit
Green cable
Door switch jig