ERROR CODE AND TROUBLESHOOTING
6 - 12
CE90 Process related
service call
Drum thermistor abnormality: The output value of the
drum thermistor-K is out of a specified range.
P. 6-99
CF10 Finisher related
service call
Communication module SRAM reading failure. [MJ-1101] P. 6-99
F070 Communication
related service call
Communication error between System-CPU and Engine-
CPU
P. 6-75
F090 Other service call SRAM abnormality on the SYS board P. 6-102
F100 HDD format error: HDD cannot be initialized normally. P. 6-102
F101 HDD unmounted: Connection of HDD cannot be
detected.
P. 6 - 1 0 2
F102 HDD start error: HDD cannot become ‘Ready’ state. P. 6-102
F103 HDD transfer time-out: Reading/writing cannot be
performed in the specified period of time.
P. 6 - 1 0 2
F104 HDD data error: Abnormality is detected in the data of
HDD.
P. 6 - 1 0 2
F105 HDD other error P. 6-102
F106 Point and Print partition damage P. 6-103
F107 /SHR partition damage P. 6-103
F108 /SHA partition damage P. 6-103
F110 Communication
related service call
Communication error between System-CPU and
Scanner-CPU
P. 6-75
F111 Scanner response abnormality P. 6-75
F120 Other service call Database abnormality: Database is not operating
normally.
P. 6 - 1 0 3
F130 Invaid MAC address P. 6-103
F200 Data Overwrite option (GP-1070) disabled P. 6-103
F350 Circuit related
service call
SLG board abnormality P. 6-103
F400 SYS board cooling fan abnormality P. 6-103
Error code Classification Contents Troubleshooting