6
© 2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455
ERROR CODE AND TROUBLESHOOTING
6 - 11
CC60 Finisher related
service call
Punch motor abnormality: The punch motor is not rotating
normally or the puncher is not moving normally.
[MJ-1025 (when MJ-6005 is installed)]
Punch motor abnormality: Punch motor is not rotating or
puncher is not shifting normally. [MJ-1024 (when MJ-
6004 is installed)]
P. 6-92
CC61 Punch motor home position detection error P. 6-77
CC71 Punch ROM checksum error P. 6-77
CC72 Punch RAM read/write error P. 6-77
CC80 Alignment motor (front) abnormality: The alignment motor
(front) is not rotating normally or the front alignment plate
is not moving normally.
Front aligning plate motor abnormality: Front aligning
plate motor is not rotating or aligning plate is not moving
normally. [MJ-1024]
Rear alignment motor abnormality: The rear alignment
motor is not rotating or the rear alignment plate is not
moving normally. [MJ-1101]
P. 6-94
CC90 Upper stack tray lift motor abnormality: The upper stack
tray lift motor is not rotating or the upper stack tray is not
moving normally.
Tray shift motor abnormality: The tray shift motor is not
rotating or the stack tray is not moving normally. [MJ-
1031]
P. 6-95
CCB0 Alignment motor (rear) abnormality: The alignment motor
(rear) is not rotating normally or the rear alignment plate
is not moving normally. [MJ-1025]
Offset motor abnormality: The offset motor is not rotating
normally. [MJ-1031]
P. 6-95
CCD0 Stack ejection motor abnormality: Stack ejection motor or
stack ejection roller is not rotating normally. [MJ-1024]
P. 6-96
CCE0 Paper trailing edge assist motor abnormality: Paper
trailing edge assist motor is not rotating or paper trailing
edge assist is not moving normally. [MJ-1024]
P. 6-96
CCF0 Gear changing motor abnormality: Gear changing motor
is not rotating normally. [MJ-1024]
P. 6-96
CCF1 Tray safety switch abnormality -
(1) The tray safety switch turned on during tray operation
(moving up or down).
(2) The tray operated with the tray safety switch turned
on.
[MJ-1031]
P. 6-97
CDC0 Punch power failure abnormality: 24 V is not applied to
the punch controller board.
[MJ-1025 (when MJ-6005 is installed)]
P. 6-97
CDD0 Folding position sensor abnormality: Automatic
adjustment of the folding position sensor can not be
performed properly. [MJ-1025]
P. 6-97
CDE0 Paddle motor abnormality: The paddle motor does not
rotate properly. [MJ-1025]
P. 6-98
CDF0 Offset tray related
service call
Initialization error of the offset tray: The home position of
the separator cannot be detected when the power is
turned ON.
P. 6 - 1 0 1
CE00 Finisher related
service call
Communication error between finisher unit and puncher
unit: Communication error between the finisher controller
PC board and punch controller PC board.
[MJ-1025 (when MJ-6005 is installed)]
Communication error between finisher and punch unit:
Communication error between finisher controller PC
board and punch controller PC board
[MJ-1024 (when MJ-6004 is installed)]
[MJ-1101 (when MJ-6101 is installed)]
P. 6-99
CE50 Circuit related
service call
Temperature/humidity sensor abnormality: The output
value of this sensor is out of a specified range.
P. 6-99