6
© 2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455
ERROR CODE AND TROUBLESHOOTING
6 - 31
Is the PFP transport clutch working? (Perform the output check in the test mode: 03-225)
l
l
l
l
l
l
l
l
l
l
l
NO 1. Check if the connector of the PFP transport clutch is disconnected.
2. Check if any of the connectors CN241 and CN244 on the PFP board
is disconnected.
3. Check if the connector CN318 on the LGC board is disconnected.
4. Check if the connector pins are disconnected and the harnesses are
open circuited.
5. Check if the conductor patterns on the PFP board and LGC board
are short circuited or open circuited.
6. Replace the PFP transport clutch.
7. Replace the PFP board.
8. Replace the LGC board.
YES
1. Check the condition of the feed roller, separation roller and pickup roller of each paper
source, and replace them if they are worn out.
2. Check the transport roller. Replace it if it is worn out.
[E360] Paper fed from the PFP lower drawer not reaching the PFP upper drawer feed sensor
Open the PFP side cover. Is there any paper in front of the PFP upper drawer feed sensor?
YES Remove the paper.
NO
Is the PFP upper drawer feed sensor working?
(Perform the input check in the test mode: 03-[FAX]OFF/[7]/[A])
l
l
l
l
l
l
l
l
l
l
l
l
NO 1. Check if the connector of the PFP upper drawer feed sensor is
disconnected.
2. Check if either of the connectors CN241 or CN243 on the PFP board
is disconnected.
3. Check if the connector CN318 on the LGC board is disconnected.
4. Check if the connector pins are disconnected and the harnesses are
open circuited.
5. Check if the conductor patterns on the PFP board and LGC board
are short circuited or open circuited.
6. Replace the PFP upper drawer feed sensor.
7. Replace the PFP board.
8. Replace the LGC board.
YES
Is the PFP feed clutch working? (Perform the output check in the test mode: 03-226)
l
l
l
l
l
l
l
l
l
l
l
NO 1. Check if the connector of the PFP transport clutch is disconnected.
2. Check if any of the connectors CN241 and CN247 on the PFP board
is disconnected.
3. Check if the connector CN318 on the LGC board is disconnected.
4. Check if the connector pins are disconnected and the harnesses are
open circuited.
5. Check if the conductor patterns on the PFP board and LGC board
are short circuited or open circuited.
6. Replace the PFP transport clutch.
7. Replace the PFP board.
8. Replace the LGC board.
YES