ADJUSTMENT
3 - 14
3.2.4 Scanner related adjustment
Make a copy, compare the result with the original and make an adjustment if the image is distorted.
[A] Image distortion
Fig. 3-13
B: 05-411 (2nd/4th drawer, A3/LD)
52±0.5 mm (0.05 mm/step)
Key in the same value for 05-410.
C: 05-488 (2nd/4th drawer, A3/LD)
200±0.5 mm (0.2 mm/step)
D: 05-440 (1st drawer, A4/LT),
441 (2nd drawer, A3/LT),
444 (3rd drawer, A3/LT),
428 (4th drawer, A4/LD),
443 (LCF, A4/LT),
442 (Bypass feed, A4/LT),
445 (Duplexing, A3/LD)
52±0.5 mm (0.4 mm/step)
E: 05-498-0 (2nd/4th drawer, A3/LD),
498-1 (1st drawer/Tandem LCF, A4/LT)
52±0.5 mm (0.05 mm/step)
Feeding direction
Feeding direction
Step 1
A
Step 2
C
B
D