ADJUSTMENT
3 - 28
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in the codes to be adjusted (language and screen) and press the [START] button.
(3) Key in the value corresponding to the density area to be adjusted (0, 1 or 2) and press the
[START] button.
0: Low density (L) 1: Medium density (M) 2: High density (H)
(4) Key in the adjustment value. (To correct the value once keyed in, press [CLEAR] button.)
(5) Press the [ENTER] or [INTERRUPT] button to store the value in memory. ¨ The equipment goes
back to the ready state.
(6) For resetting the value, repeat step (2) to (5).
(7) Let the equipment restart and perform printing job.
(8) If the image density has not been attained, repeat step (1) to (7).
3.4.3 Image density adjustment
Adjust the image density level when normal printing (Toner save: Disable) and (Toner save: Enable).
< Adjustment Mode (05) >
<Procedure>
Procedure is same as that of  P.3-27 "3.4.1 Adjustment of smudged/faint text".
Normal
Toner Saving
mode
Item to be adjusted Remarks
PS/PCL PS PCL
663 664 665 Image density adjustment The image density level in the Printer function can
be set.
The smaller the value is, the lighter the density of
image becomes.
Acceptable values: 0 to 255.

Table of Contents

Other manuals for Toshiba E-STUDIO520

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba E-STUDIO520 and is the answer not in the manual?

Toshiba E-STUDIO520 Specifications

General IconGeneral
BrandToshiba
ModelE-STUDIO520
CategoryAll in One Printer
LanguageEnglish

Related product manuals