ADJUSTMENT
3 - 57
3
(3) Close the RADF to check that the positioning
pins fit smoothly into the holes on the RADF.
If they do not, adjust them according to the
following procedure.
Fig. 3-54
(4) Loosen the stepped screw 1 turn and 2
screws on the adjustment plate a half turn
(status of temporary fixing).
Fig. 3-55
(5) Remove the stepped screw at the rear of
right-hand hinge.
Fig. 3-56
2 screws: Half turn
Stepped screw: 1 turn