EasyManua.ls Logo

Toshiba E-STUDIO520 - Page 40

Toshiba E-STUDIO520
650 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
e-STUDIO520/523/600/603/720/723/850/853 © 2005 - 2007 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 14
F104 Other service call HDD data error: Abnormality is detected in the data of the
HDD.
Ch.5.1.13
F105 Other HDD errors Ch.5.1.13
F106 Point and Print partition damage Ch.5.1.13
F107 /BOX partition damage Ch.5.1.13
F108 /SHA partition damage Ch.5.1.13
F110 Communication
related service call
Communication error between System-CPU and Scan-
ner-CPU
Ch.5.1.9
F111 Scanner response abnormality Ch.5.1.9
F120 Other service call Database abnormality: Databases do not run normally. Ch.5.1.13
F130 Invalid MAC address Ch.5.1.13
F200 Data overwrite kit (GP-1060) is taken off Ch.5.1.13
Error code Classification Contents Troubleshooting
05/05