TROUBLESHOOTING
5 - 41
5
[E870] RADF open jam
Is the connector CN11 on the ADF board disconnected?
YES Connect the connector.
NO
Is the harness between the ADF board and RADF open/close sensor open-circuited?
YES Replace the harness.
NO
Is the RADF open/close sensor working improperly?
YES Replace the RADF open/close sensor.
NO
Is the harness between the ADF board and APS operation sensor open-circuited?
YES Replace the harness.
NO
Is the APS operation sensor working improperly?
YES Replace the APS operation sensor.
NO
Replace the ADF board.