2. Copier-specific Adjustments
* Set the value in increments of approximately 10, while checking the copy image until the optimum value is
obtained.
* The value for the code corresponding to the original mode (Text/Photo, Text, or Printed image) will affect
the copy image quality in the Full color mode and the Auto color mode.
* The subcode varies according to the area where the density is adjusted. Refer to the table below and set the
subcode for the area to be adjusted.
Subcode
Area where the density is adjusted
0
Low-density area
1
Medium-density area
2
High-density area
Caution after the adjustment
Nothing in particular.
Remarks
Enter a value within the recommended value range mentioned in the procedures. Otherwise, it may cause a loss
in MFP performance, including degradation in the image quality and a reduction in the life of the consumables
If the adjustment causes a toner fixing problem, decrease the values for codes 05-7905 to 7911.