5.9 To Eliminate Shading around Scanned Images
Explanation
The white void amount around the scanned image is adjusted. Since the void amount is very small in the stored
image in scanning, shading may appear around the scanned image due to a slight difference of the original size.
This can be eliminated by adjusting the setting value.
* The setting value is applied to all resolutions and color modes.
Procedures
* All the steps in the adjustment procedure shall be performed by the service technician.
(1) Select [05 ADJUSTMENT MODE]. Change the value for the code [7489] to adjust the white void amount
around the scanned image.
[05] code Setting value (Target)
The setting value "1" corresponds to 1 dot with 600
dpi, that is "24" to 1 mm.
0 to 255 0
* When the value increases, the white void around the scanned image becomes wider, and the data on the image
decrease.