e-STUDIO5506AC/6506AC/7506AC (Ver01) © 2016, 2017 TOSHIBA TEC CORPORATION All rights reserved
5-19
5. Scanning-specific Adjustments
(2) Select [05 ADJUSTMENT MODE] to adjust the values in the Custom mode, in order to obtain the image
quality the user desires.
Select the necessary value for [05] code in the table below.
Color mode [05] code
Adjustment
Acceptable
value range
Default
Black
05-7441 Background adjustment
0 to 255
128
05-7470 Sharpness adjustment 128
05-7475 Manual density adjustment center value 128
05-7478 Automatic density adjustment 128
05-7480 Gamma curve balance adjustment 128
Full color
05-8370 Background adjustment 0 to 255 128
05-8371 Fine adjustment of black density 0 to 4 0
05-8372 RGB conversion method selection 0 to 3 0
05-8373 Saturation adjustment
0 to 255
128
05-8375 Sharpness adjustment 128
05-8380 Manual density adjustment center value 128
* For further information regarding the codes, refer to the Service Manual.
<Note> Select the code for the Custom mode option, in order to adjust the value for [05] code in the
Custom mode. Never adjust any values for [05] code in existing original mode.
After adjusting the value in the Custom mode, use the next procedure.
(3)When scanning the original, press [SCAN SETTING] on the Control Panel. Select "Custom" from
among the original mode options.
Caution after the adjustment
Nothing in particular.