e-STUDIO5506AC/6506AC/7506AC (Ver01) © 2016, 2017 TOSHIBA TEC CORPORATION All rights reserved
5-17
5. Scanning-specific Adjustments
Procedures
* The service technician must perform all adjustments.
(1) Select [05 ADJUSTMENT MODE]. Change the values for codes [7480] and [7485 to 7488] to adjust the
gamma curve balance of the low-, medium- and high-density areas.
Color mode Original mode
Black
Text/Photo 05-7485 0/1/2
Set a value smaller than 128
Set a value larger than 128
to increase the density.
0 to 255 128
Photo 05-7487 0/1/2
User custom 05-7480 0/1/2
Gray scale --- 05-7488 0/1/2
* Set the value in increments of approximately 20, while checking the scanned-in image until the optimum
value is obtained.
* The subcode varies according to the area where the density is adjusted. Refer to the table below and set the
subcode for the area to be adjusted.
Area where the density is adjusted
* Gradation in the Black mode will vary, if the medium-density area is mainly adjusted. But remember that
adjusting the low- or high-density area will rarely affect the gradation in the Black mode.
Caution after the adjustment
Nothing in particular.