e-STUDIO5506AC/6506AC/7506AC (Ver01) © 2016, 2017 TOSHIBA TEC CORPORATION All rights reserved
5-24
5. Scanning-specific Adjustments
When the noise reduction level for each [Low], [Middle] or [High] is changed, the service technician must
perform the following step.
(2) Enter [05 ADJUSTMENT MODE] and change the setting values for the codes from [7400] to [7404] and
from [8412] to [8415] to adjust the noise reduction level.
Color mode Original mode
[05]
Code
Recommended
value
* Setting "200" provides the weakest noise reduction level, while setting "1" provides the strongest one.
Moreover, when "0" is set for the setting value, this function becomes disabled.
* The noise reduction level for each [Low], [Middle] or [High] of [ADF Scan Noise Reduction] set from the
control panel is changed. Setting the recommended value provides the most effective result.
After changing the setting value, perform scanning and check its image quality.
Caution after the adjustment
Perform the adjustment while checking the scanned images since the adjustment may decrease the
reproducibility of fine characters and lines.