1. General Adjustments – Copying, Printing and e-Filing (Output from Box)
(b) Set "5" or "3" for code 08-2508 to increase the frequency of image quality control, in response to a
change in humidity.
* Image quality control will be performed, when the drum temperature changes in accordance with the
difference from the previous image quality control. If the difference in the drum temperature exceeds
the specified value after a print job is performed, image quality control is performed.
• After setting the value for code 08-2505, forcibly perform image quality control, as follows:
Select [05 ADJUSTMENT MODE]. Select code [2742]. Press the [START] button.
(1)-3. To Have Uniform Variations in the Image Quality after Return from the Auto Power Save
Mode:
Change the value of the [08] code [2507] to change the conditions for starting image quality control (shorten
the period of time the MFP is left unused) after the MFP was recovered from the auto power save mode, so
that the image quality control will be easily performed.
Image quality control is performed before the start of a job.
For a more stable image quality on halftones, switch the image quality control to start to the Full Mode with
code 08-2492. (0: Disabled, 1: Short, 2: Full)