184 HX7+ ASD Installation and Operation Manual
Communication Baud Rate (TTL)
Program Communication Communication Settings
This parameter plays a role in the setup of the communications network by 
establishing the Baud Rate of the communications link.
The communications network includes other ASDs and Host/Control computers 
that monitor the status of the ASD(s), transfers commands, and loads or 
modifies the parameter settings of the ASD.
Changes made to this parameter require that the power be cycled (Off then On) 
for the changes to take effect.
Direct Access Number —  F800
Parameter Type — Numerical
Factory Default — 9600
Changeable During Run — Ye s
Minimum — 1200
Maximum — 9600
Units — BPS
Parity
Program Communication Communication Settings
This parameter plays a role in the setup of the communications network by 
establishing the Parity setting of the communications link.
The communications network includes other ASDs and Host/Control computers 
that monitor the status of the ASD(s), transfers commands, and loads or 
modifies the parameter settings of the ASD.
Changes made to this parameter require that the power be cycled (Off then On) 
for the changes to take effect.
Settings:
0 — No Parity
1 — Even Parity
2 — Odd Parity
Direct Access Number —  F801
Parameter Type — Selection List
Factory Default — Even Parity
Changeable During Run — Ye s
ASD Number
Program Communication Communication Settings
This parameter plays a role in the setup of the communications network by 
assigning an identification (ID) number to each ASD in the communications 
network.
The communications network includes other ASDs and Host/Control computers 
that monitor the status of the ASD(s), transfers commands, and loads or 
modifies the parameter settings of the ASD.
Changes made to this parameter require that the power be cycled (Off then On) 
for the changes to take effect.
Direct Access Number —  F802
Parameter Type — Numerical
Factory Default — 0
Changeable During Run — Ye s
Minimum — 0
Maximum — 255
RS232/RS485 Communications Time Out Time
Program Communication Communication Settings
This parameter plays a role in the setup of the communications network by 
setting the time that no activity may exist over the communications link before 
the link is severed (Time Out).
The communications network includes other ASDs and Host/Control computers 
that monitor the status of the ASD(s), transfers commands, and loads or 
modifies the parameter settings of the ASD.
Changes made to this parameter require that the power be cycled (Off then On) 
for the changes to take effect.
Direct Access Number —  F803
Parameter Type — Numerical
Factory Default — 0
Changeable During Run — Ye s
Minimum — 0
Maximum — 100
Units — Seconds
F800 F803