4 Replacement Procedures 4.23 LCD unit / FL inverter
4-76 TECRA M3 Maintenance Manual (960-507)
4. Connect the LCD cable to the connector on the back of the LCD unit. Stick the copper
tape on the LCD cable.
CAUTION:
5. Seat the LCD unit and secure it with the following screws.
? M2?4Z S-FLAT HEAD screw ?4
6. Stick the four mask seals on the sides of the LCD unit.
7. Connect the FL cable and the HV cable to the FL inverter.
8. Seat the FL inverter and stick the insulator on the FL inverter of the FL cable side.
9. Secure the FL inverter with the following screw.
? M2?4Z S-FLAT HEAD screw ?1
10. Install the LCD mask while hooking the latches.
11. Secure the LCD mask with the following screws.
? M2.5?6B FLAT HEAD screw ?2
When sticking the
copper tape, do not
cover the aluminum
cover.
Align the bottom edge of
copper tape with the