4 Replacement Procedure 4.26 Fluorescent Lamp
4-96 TECRA M3 Maintenance Manual (960-507)
4.26.2 Replacing the 14.1-inch XGA TMD Fluorescent Lamp
CAUTION: When replacing the fluorescent lamp, wear finger covers or gloves to avoid
contaminating or damaging the LCD panel. Be careful not to let dust or
other foreign substance into the module.
Disassembling the 14.1-inch XGA TMD Fluorescent Lamp
To disassemble the 14.1-inch XGA TMD fluorescent lamp, follow the steps below and refer to
Figure 4-69 to 4-79.
Peeling off the tapes and insulation sheets
1. Place the LCD module face down on a flat table that has no alien substance on it. Make
sure there is no dust on the desk to avoid scratching the surface of the LCD module. Place
a protection sheet (such as soft cloth) on the surface.
2. In the order (1), (2) shown in Figure 4-69, remove the tapes for fixing the FL cable and
lump clip.