EasyManua.ls Logo

Toshiba TOSVERT VF-PS1 - Auto-stop Functions

Toshiba TOSVERT VF-PS1
317 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E6581386
F-17
6
6.9 Auto-stop in case of lower-limit frequency continuous operation
(Sleep/Wake-up function)
 : Time limit for lower-limit frequency operation
Function
If operation is carried out continuously at a frequency below the lower-limit frequency (

) for the period
time set

, theinverter will automatically slow down the motor to a stop.

” is always displayed on the operation panel. (Blinking alternately)
The auto-stop function will be disabled when the frequency command value reaches over the lower limit
frequency (

)+0.2Hz or the operation command is turned to off.
[Parameter setting]
Title
Function Adjustment range Default setting

Auto-stop in case of lower-limit frequency
continuous operation

:None

~  sec.

Output frequency [Hz]
  
Time [s]
Operation signal (F-CC)
ON
OFF

+0.2Hz

Note: This function is enabled even at the start of operation and during switching between forward and reverse run.

Table of Contents

Related product manuals