K-32
E6581386
11
[28] My function [4/5] Sensorless vector/PG feedback control (●:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Vector
control
PM
control
V/f Constant
Reference
0947 Output function target 61 Same as 1/1 0 Enabled ●/● ● ● *1
0948 Input function command 62 Same as 1/1 0 Enabled ●/● ● ● *1
0949 Input function target 62 Same as 1/1 0 Enabled ●/● ● ● *1
0950 Input function command 63 Same as 1/1 0 Enabled ●/● ● ● *1
0951 Input function target 63 Same as 1/1 0 Enabled ●/● ● ● *1
0952 Output function assigned object 6 Same as 1/1 0 Enabled ●/● ● ● *1
0953 Input function target 71 Same as 1/1 0 Enabled ●/● ● ● *1
0954 Input function command 72 Same as 1/1 0 Enabled ●/● ● ● *1
0955 Input function target 72 Same as 1/1 0 Enabled ●/● ● ● *1
0956 Input function command 73 Same as 1/1 0 Enabled ●/● ● ● *1
0957 Input function target 73 Same as 1/1 0 Enabled ●/● ● ● *1
0958 Output function assigned object 7 Same as 1/1 0 Enabled ●/● ● ● *1
0959 Analog input function target 11
0:Disabled
1:VI/II
2:RR/S4
3:RX
4:Optional AI1+, Optional AI1-
5:Optional AI2
6:Internal memory1
1/1 0 Enabled ●/● ● ● *1
0961 Analog function assigned object 11
0:Disabled
1:Acceleration
2:Upper limit frequency ()
3:Acceleration multiplication factor
4:Deceleration multiplication factor
5:Manual torque boost ()
6:OC stall ()
7:Thermal protection ()
8:Speed loop P gain ()
9:Drooping gain ()
10:PID P gain ()
1/1 0 Disabled ●/● ● ● *1
*1: For details, refer to Instruction Manual (E6581335) specified in Section 6.36.