RMON Configurations
User Guide     889
Configuring SNMP & RMON
Falling Threshold Set the falling threshold of the variable. Valid values are from 1 to 
2147483647. When the sampling value or the difference value is below the 
threshold, the system will trigger the corresponding Falling Event.
Note:
 The falling threshold should be less than the rising threshold.
Falling Event Specify the index of the Event entry that will be triggered when the sampling 
value or the difference value is below the preset threshold. The Event entry 
specified here should be enabled first.
Alarm Type Specify the alarm type for the entry. 
Rising: The alarm is triggered only when the sampling value or the difference 
value exceeds the rising threshold.
Falling: The alarm is triggered only when the sampling value or the difference 
value is below the falling threshold.
All: The alarm is triggered when the sampling value or the difference value 
exceeds the rising threshold or is below the falling threshold.
3)  Enter the owner name, and set the status of the entry. Click Apply.
Interval (seconds) Set the sampling interval. Valid values are from 10 to 3600 seconds.
Owner Enter the owner name of the entry with 1 to 16 characters.
Status Enable or disable the entry.
Enable: The entry is enabled.
Disable: The entry is disabled.
5.2  Using the CLI
5.2.1  Configuring Statistics
Step 1 configure