Model Number Descriptions
UNT-SVX07E-EN 11
Digit 25 — Auxiliary Control
Valve
X = Field-supplied N/O control valve
Y = Field-supplied N/C control valve
Z = Field supplied 3-wire modulating
control valve
1 = Field-supplied analog valve
(2-10VDC)
A = 2-way, 2-position, NO (30 psig)
Cv = 2.3
B = 3-way, 2-position, NO (28 psig)
Cv = 3.0
C = 2-way, 2-position, NC (30 psig)
Cv = 2.3
D = 3-way, 2-position, NC (20 psig)
Cv = 4.4
E = 2-way, 2-position, NO (50 psig)
Cv = 1.0
F = 3-way, 2-position, NO (28 psig)
Cv = 1.5
G = 2-way, 2-position, NC (50 psig)
Cv = 1.0
H = 3-way, 2-position, NC (28 psig)
Cv = 1.5
J = 2-way, modulating, Cv=0.6
(60 psig)
K = 3-way, modulating, Cv=0.6
(60 psig)
L = 2-way, modulating, Cv=1.1
(60 psig)
M = 3-way, modulating, Cv=1.1
(60 psig)
N = 2-way, modulating, Cv=2.3
(60 psig)
P = 3-way, modulating, Cv=2.7
(60 psig)
Q = 2-way, modulating, Cv=3.3
(60 psig)
R = 3-way, modulating, Cv=3.8
(60 psig)
0 = Without heating control valves
2 = 2-way, analog(2-10VDC), Cv=0.6
(60 psig)
3 = 3-way, analog(2-10VDC), Cv=0.6
(60 psig)
4 = 2-way, analog(2-10VDC), Cv=1.1
(60 psig)
5 = 3-way, analog(2-10VDC), Cv=1.1
(60 psig)
6 = 2-way, analog(2-10VDC), Cv=2.3
(60 psig)
7 = 3-way, analog(2-10VDC), Cv=2.7
(60 psig)
8 = 2-way, analog(2-10VDC), Cv=3.3
(60 psig)
9 = 3-way, analog(2-10VDC), Cv=3.8
(60 psig)
Digit 26 — Piping Packages/End
Valves
0 = Without piping
A = Basic ball valve supply and
return
B = Basic ball valve supply, manual
circuit setter return
D = Deluxe ball valve supply and
return
E = Deluxe ball valve supply, manual
circuit setter return
Digit 27 — Control Type
A = Fan speed switch
D=Tracer ZN 010
E=Tracer ZN 510
F = Tracer ZN 520
H = CS T-Stat Interface
J = Tracer UC400, single zone VAV
K = Tracer UC400, with wireless
comm
Digit 28 — Control Option
0=None
D = Unit-mounted fan speed switch,
line voltage
K = Wall-mounted fan speed switch,
line voltage
V = Unit-mounted zone sensor
(OALMH and setpoint dial)
3 = Unit-mounted fan speed switch,
low voltage
W = Wall-mounted zone sensor
(OALMH and setpoint dial)
X = Unit-mounted fan switch and
wall-mounted setpoint dial
Y = Unit-mounted fan switch and
wall-mounted (setpoint, comm)
Z = Unit-mounted temp sensor
(OALMH, SP, ON/CNC)
1 = Wall-mounted temp sensor
(OCC/UNOCC, COMM)
2 = Wall-mounted temp sensor
(OALMH,SP,O/C,COMM)
4 = Wall-mounted sensor (SP,
OALMH, O/C,COM)
6 = Wireless temp sensor, unit
receiver (SP)
7 = Wireless display sensor, unit
rec (OALMH)
Digit 29 — Drain Pan Material
3 = Polymer drain pan
4 = Stainless steel drain pan
Digit 30 — FLA Motor Option
0 = Standard FLA ECM
A = Reduced FLA ECM
Digit 31 — Control Function 2
0 = Without occupant call or IAQ
status
Digit 32 — Control Function 3
0 = Without occupied/unoccupied or
condensate overflow
2 = Condensate overflow detection
Digit 33 — Control Function 4
0 = Without smoke input or low limit
detect
2 = Low limit detection
Digit 34 — Control Function 5
0 = Without external interlock or fan
status
Digit 35 — Control Function 6
0 = Without motion input or filter
status
2 = Filter status

Table of Contents

Other manuals for Trane UniTrane Fan-Coil

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane UniTrane Fan-Coil and is the answer not in the manual?

Trane UniTrane Fan-Coil Specifications

General IconGeneral
BrandTrane
ModelUniTrane Fan-Coil
CategoryHeater
LanguageEnglish

Related product manuals