Safety
2.7.2 Key switch
Turning the key switch to the "0" position powers off the motor, laser source and electric system. Operation of the
machine by unauthorized persons can be prevented by removing the key switch.
2.7.3 Emergency stop button
Pressing the emergency stop button immediately switches off the circuit.
The laser beam is interrupted and all movements are stopped.
The task of the emergency stop switch is:
First priority: Prevention of danger to the operating personnel.
Second priority: Prevention of damage or destruction of the machine and/or material.
ACKNOWLEDGE THE EMERGENCY STOP SWITCH
1. Turn the emergency stop switch counterclockwise to
unlock it so that the green marking is visible.
2. Restart the laser system using the key switch.
2.7.4 Interlock safety switches
Interlock safety switch query the closed status of the acrylic top lid, side panels and front door. If the safety devices are
open or not present, the laser cannot be operated. However, the pilot laser stays active.
2.7.5 Acrylic top lid
The type of acrylic top lid depends on the laser type. It protects the operator from uncontrolled emission of dangerous
laser radiation.
2.7.6 Side cover
The side panels protect from laser light and must always be closed and properly attached.
21