Disassembly
11 Disassembly
Warning
Danger of injury when disassembling the machine.
There is danger of injury when disassembling the machine.
Always wear suitable protective clothing (e.g. safety goggles, safety shoes, safety gloves).
Warning Dangerous electrical voltage
Electric current.
The machine must be disconnected from the main power supply.
Notice
– Always use suitable tools to disassemble the machine.
– Mind the springs.
– Follow chapter "Disposal".
PROCESS:
1. Remove all workpieces from the system.
2. Switch off the main switch at the back of the machine.
3. Remove the exhaust system.
4. Disconnect all cables at the back of the machine.
5. Disconnect the air assist and water cooling system.
6. Remove the glass laser source.
76