Page #42 background imageLoading...
Page #42 background image
3-14
ASPHALT SURFACE PREPARATION
It is possible, but usually not necessary, to take direct transmission
readings on asphalt. Drilling a hole in asphalt can be difficult, and
may require the use of a drill (rather than the drill rod) if the asphalt
has cooled and hardened.
Under normal conditions, a backscatter reading provides an accurate
measurement of asphalt density.
Find a smooth, level location on the asphalt. The operator may
want to fill the voids on open mixes with sand or cement. Take
care to leave the asphalt exposed. The gauge base must rest on
the asphalt, not the fill material!
Ensure that the gauge does not “rock.” It must remain steady. If
rocking occurs, find a more suitable test site. If taking a
measurement around a core, the gauge may be moved a few
inches away from the hole to level the gauge.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Troxler 3430 and is the answer not in the manual?

Troxler 3430 Specifications

General IconGeneral
Measurement PrincipleNuclear
Power SourceRechargeable battery
DisplayLCD
Data StorageInternal memory
TypePortable
Material MeasuredSoil, Asphalt
Moisture Measurement Range0 to 60%
Operating Temperature-10 to 50°C
SourceCesium-137