Model 3430
1-7
STORAGE SITE SELECTION
When deciding where to store the gauge, take into consideration the
rules governing the storage of low-level radioactive devices that are
set forth by your regulatory agency and the conditions of your gauge
license.
The handle should be locked and the gauge stored in its
transport case.
It is recommended that the gauge and transport case be stored at
least 15 ft (5 m) from work areas, preferably in a locked
closet/storage area in a dry location (indoors).
The storage area should be marked with a radiation sign that
reads “CAUTION RADIOACTIVE MATERIALS(can be
obtained from Troxler).
The storage of a nuclear gauge in a motor vehicle is not
recommended.
INTRODUCTION

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Troxler 3430 and is the answer not in the manual?

Troxler 3430 Specifications

General IconGeneral
Measurement PrincipleNuclear
Power SourceRechargeable battery
DisplayLCD
Data StorageInternal memory
TypePortable
Material MeasuredSoil, Asphalt
Moisture Measurement Range0 to 60%
Operating Temperature-10 to 50°C
SourceCesium-137