EasyManua.ls Logo

Troxler 3430 - Special Calibration Function

Troxler 3430
142 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Model 3430
5-7
SPECIAL CALIBRATION
For information on performing a special calibration, see Chapter 4.
SPECIFIC GRAVITY
The specific gravity of a solid is defined as the density of the
material divided by the density of water. The Specific Gravity
function allows the operator to input the specific gravity of a
material into the gauge. This value (SG) is used in the calculation of
% Air Voids and Void Ratio (see Chapter 3).
To access the Special functions, press SPECIAL.
To access the Specific Gravity feature, press the down arrow five
times and press
START/ENTER.
To change the value of the flashing digit, use the up and down
arrows. To accept the flashing value and select the next digit, press
START/ENTER.
If a value is not entered, the default value is the specific gravity for
soil grains (2.70).
SG = 2.70