INFO, TEST, AND EDIT MODE
13
3. To navigate between digits, use the L3 and R3
soft keys for auto-on time and the L4 and R4
soft keys for auto-off time.
4.
U
se the number keys to enter the desired hour
and minute for the oven to automatically turn
on or off
.
5. Select “Save” to save your changes or press the
B
ack/Stop key to cancel.
Test Mode - Testing Oven Parts
F
r
om screen 2 of the Info Mode (Figure 13, page
11), pr
ess the L1 soft key to access Test Mode
(F
igur
e 16). When prompted, enter the password
9 4 2 8
and press the Enter key. From Test Mode,
the o
ven’s components can be tested independently,
or a comprehensive/selective self-test can be run.
U
nless otherwise specified, idle airflow is set to
10% and the stirrer motor is turned on.
NOTE: To view fault counts, go to screen 1 of the
Info Mode (Figure 12, page 11).
Magnetron Test
P
ress and hold the L1 soft key (Figure 16) to turn
on the magnetrons. To turn off the magnetrons,
release the L1 soft key.
Top Blower
P
ress the L2 soft key (Figure 16) to increase top
blo
wer speed in 10% increments.
NO
TE: While the top blower is being tested, the
bottom blo
w
er remains at 10% idle airflow.
Bottom Blower
Press the L3 soft key (Figure 16) to increase bottom
blo
wer speed in 10% increments.
NO
TE: While bottom blower is being tested, the
top blo
w
er remains at 10% idle airflow.
Heaters
Press and hold the L4 soft key (Figure 16) to turn
the heaters on. R
elease the key to turn them off.
Stirrer
P
r
ess the R1 soft key (Figure 16) to turn the stirrer
on/off.
S
ta
tus Indicators
Figure 16. The status indicators are located at the
bottom of the
Test Mode screen, and consist of:
-
P = P
rimary switch (backlit = open)
-
S = Secondary switch (backlit = open)
-
M = Monitor switch (backlit = open)
-
t = Magnetron thermostat (backlit = open)
-
H = Heaters (backlit = off)
-
B = Bottom blower (backlit = off)
- T = Top blower (backlit = off)
-
W = Microwave (backlit = off)
I
n F
igure 16:
- All three door switches are engaged (closed).
-
The heaters ar
e off.
-
Both blower motors are on.
-
M
icrowave is not being used.
T
urning Diagnostic Mode On/Off
Press the R2 soft key (Figure 16) to place the oven
in D
iagnostic Mode. When in Diagnostic Mode,
the oven displays additional cooking parameters
during a cook cy
cle, including:
-
Event currently being cooked
- Time left per event
- % wave, % top air, and % bottom air
- Status indicators
-
Group and recipe name
-
CC temperature
-
CC set point
F
or normal o
ven operation, ensure Diagnostic
Mode is turned off.
F
igur
e 16: Test Mode