TurboChef NGO/SOTA - Test Mode and Manufacturing Tests

TurboChef NGO/SOTA
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INFO, TEST, AND EDIT MODE
13
3. To navigate between digits, use the L3 and R3
soft keys for auto-on time and the L4 and R4
soft keys for auto-off time.
4.
U
se the number keys to enter the desired hour
and minute for the oven to automatically turn
on or off
.
5. Select “Save” to save your changes or press the
B
ack/Stop key to cancel.
Test Mode - Testing Oven Parts
F
r
om screen 2 of the Info Mode (Figure 13, page
11), pr
ess the L1 soft key to access Test Mode
(F
igur
e 16). When prompted, enter the password
9 4 2 8
and press the Enter key. From Test Mode,
the o
vens components can be tested independently,
or a comprehensive/selective self-test can be run.
U
nless otherwise specified, idle airflow is set to
10% and the stirrer motor is turned on.
NOTE: To view fault counts, go to screen 1 of the
Info Mode (Figure 12, page 11).
Magnetron Test
P
ress and hold the L1 soft key (Figure 16) to turn
on the magnetrons. To turn off the magnetrons,
release the L1 soft key.
Top Blower
P
ress the L2 soft key (Figure 16) to increase top
blo
wer speed in 10% increments.
NO
TE: While the top blower is being tested, the
bottom blo
w
er remains at 10% idle airflow.
Bottom Blower
Press the L3 soft key (Figure 16) to increase bottom
blo
wer speed in 10% increments.
NO
TE: While bottom blower is being tested, the
top blo
w
er remains at 10% idle airflow.
Heaters
Press and hold the L4 soft key (Figure 16) to turn
the heaters on. R
elease the key to turn them off.
Stirrer
P
r
ess the R1 soft key (Figure 16) to turn the stirrer
on/off.
S
ta
tus Indicators
Figure 16. The status indicators are located at the
bottom of the
Test Mode screen, and consist of:
-
P = P
rimary switch (backlit = open)
-
S = Secondary switch (backlit = open)
-
M = Monitor switch (backlit = open)
-
t = Magnetron thermostat (backlit = open)
-
H = Heaters (backlit = off)
-
B = Bottom blower (backlit = off)
- T = Top blower (backlit = off)
-
W = Microwave (backlit = off)
I
n F
igure 16:
- All three door switches are engaged (closed).
-
The heaters ar
e off.
-
Both blower motors are on.
-
M
icrowave is not being used.
T
urning Diagnostic Mode On/Off
Press the R2 soft key (Figure 16) to place the oven
in D
iagnostic Mode. When in Diagnostic Mode,
the oven displays additional cooking parameters
during a cook cy
cle, including:
-
Event currently being cooked
- Time left per event
- % wave, % top air, and % bottom air
- Status indicators
-
Group and recipe name
-
CC temperature
-
CC set point
F
or normal o
ven operation, ensure Diagnostic
Mode is turned off.
F
igur
e 16: Test Mode
MAG O F F
HEAT ERS O F F
BOT B LOWE R 10%
TOP B LOWE R 10%
TES T MODE
STI R R ER ON
VOLTAGE 208 VAC
MANU FACTUR I NG
DIAG N O STIC O N
PSM tHBT W CC = 2 1 0F
R1
R2
R3
R4
L1
L2
L3
L4

Table of Contents