OVEN SYSTEMS
21
NOTE: Do not push one end at a time, which
could cause the opposite end to lift away fr
om
the flange.
3. Re-tighten the hex screws.
4. Pull the door open only 0.25” (6 mm) and let go
of the handle.
The door must completely snap shut on its o
wn.
If the
door sticks and for
ce is needed to finish closing it, it is
out of adjustment.
W
ARNING: Perform a microwave leakage test
(page 22) after adjusting the o
ven door.
I
nterlock Switches
The primary, secondary, and monitor interlock
switches engage and disengage in sequence to ensur
e
a proper seal. When the door is opened, the switch
sequence is P, S, M. Subsequently, the sequence is M,
S, P when the door is closed.
Adjusting the Primary, Secondary, and
Monitor Switches
WARNING: This procedure is performed while
the o
ven is hot. To avoid burns, be careful when
adjusting the switches.
U
se the following procedure to adjust the primary,
secondary, and monitor switches. The secondary
switch is located on the left side hinge assembly and
the monitor switch is located on the right side hinge
assembly. The primary switch is located on the
upper-left corner of the o
v
en and utilizes an actuator
(attached to the door) and toggle assembly (attached
to the chassis) to engage (F
igure 29). See page A-8 of
the Appendix for switch assembly detail.
1. Ensure the oven has been at operating temperature
for at least fifteen minutes.
2. If adjusting the primary switch, confirm the
primar
y switch
’
s latch toggle is in the correct
position.
a. Visually inspect the latch toggle position and
verify it is angled at no less than 85° and no more
than 90° in r
efer
ence to the fr
ont flange (oven
face). See Figure 29.
b
. If the toggle is less than 85° or greater than 90°,
corr
ect the toggle's position b
y installing a
spacer/shim (the mor
e distance from the flange,
the less angle on the toggle):
- NGC-1169-1: Shim, 0.030” (0.762 mm)
- NGC-1169-2: Shim, 0.045” (1.143 mm)
c. Verify the position of the toggle by opening and
closing the o
ven door several times.
3. Adjust the switch(es):
a. Enter Test Mode (page 13).
b
. Open the oven door and verify P, S, and M
disengage in sequence.
c.
Close the oven door and verify M, S, and P
engage in sequence.
d.
I
f the switches do not engage or disengage in
sequence, close the door and adjust the
necessary switch(es) by loosening the two #4-40
screws and #8-32 screw until the proper
sequence is achieved.
NOTE: DO NOT allow the switch paddle to rest on
the body of the switch in the closed door position.
The final adjustment requires a minimum of a
0.030” (0.762 mm) gap to av
oid over-travel and
bent/damaged switches.
4.
Open and close the door several times to verify
the switch gap.
5.
Energize the microwave system and open the
o
ven door.
6.
V
erify the W indicator is backlit, meaning the
micr
owave system turns off when the door is
open.
7.
P
erform a microwave leakage test (page 22).
F
igur
e 29: Primary Switch Adjustment
0.030” (0.762 mm) Gap
85° - 90° angle