14 INFO
,
TEST
, AND EDIT MODE
M
anufac
turing Mode
F
r
om Test Mode, press the R3 soft key (Figure 16,
page 13) to place the oven in Manufacturing Mode
(F
igure 17). When in Manufacturing Mode, the fol-
lowing tests and settings can be accessed:
- Microwave leakage test
-
M
icrowave power test
- Burn in
-
Serial number edit
- Self test
- Enable/disable voltage display
- Erase/default oven settings
-
Temperature measurement (°F or °C)
Microwave Leakage Test
P
ress the L1 soft key (Figure 17) to initiate the
micr
owave leakage test. The oven will warm up to
500°F (260°C).
When warmup is complete, inser
t
the water load. Follow the steps on page 22.
M
icr
owave Power Test
For manufacturer use only.
Bur
n In
P
ress the L3 soft key (Figure 17) to initiate a 25-
minute burn in (F
igure 19). This feature helps
ensur
e all cavity walls reach thermal equilibrium
befor
e testing is conducted. B
urn in should not be
initiated in the field unless instructed by TurboChef.
Serial Number Edit
P
r
ess the L4 soft key (Figure 17) to access the “Edit
Serial Number” screen (Figure 20). To edit the serial
number:
- Use the number/letter keys to change a
character. After one second, the cursor will
adv
ance to the next character
.
- Press the R2 soft key to advance to the next
character
.
- Press the L2 soft key to return to the previous
character
.
-
Press the R4 soft key to save the changes or the
L4 soft key to cancel.
S
elf Test
Press the R1 soft key (Figure 17) to access the Self
T
est scr
een (Figure 21, page 15). From the Self Test
screen:
- L1 soft key initiates a comprehensive self test.
The oven will check the door switches, blowers,
magnetr
ons, and heaters in sequence.
- L2 soft key initiates a door switch test only.
-
L3 soft key initiates a blower test only.
-
L4 soft key initiates a magnetron test only.
-
R1 soft key initiates a heater test only.
When each test completes, the o
ven will display
PASS or FAIL.
F
igure 17: Manufacturing Mode
MW L E AK TEST
SER I A L NO. E D I T
BUR N IN
MW P W R TEST
MANU FACTUR I NG MO D E
SEL F TE S T
FA H R ENHEI T 21F
ERA S E /DEFAU LT
VOLT ON
PSM tHBT W
R1
R2
R3
R4
L1
L2
L3
L4
F
igure 18: Microwave Leak Test
MW L E AK TEST
WA R M ING 1 7 1 F
SER I A L NO. E D I T
BUR N IN
MW P W R TEST
MANU FACTUR I NG MO D E
SEL F TE S T
FA H R ENHEI T 21F
ERA S E /DEFAU LT
VOLT ON
PSM tHBT W
R1
R2
R3
R4
L1
L2
L3
L4
Figure 19: Burn In
MW L E AK TEST
SER I A L NO. E D I T
BUR N IN
PLE A S E WAI T
WA RMING U P: 18 8 F
MW P W R TEST
MANU FACTUR I NG MO D E
SEL F TE S T
FA H R ENHEI T 21F
ERA S E /DEFAU LT
VOLT ON
PSM tHBT W
R1
R2
R3
R4
L1
L2
L3
L4
Figure 20: Serial Number Edit
CAN C E L
S/N : i1-X3D 0 0 014 >
SER I A L NUM B ER ED I T :
SAVE
R1
R2
R3
R4
L1
L2
L3
L4