Parameterizing and Configuring
Parameters_TBEN_S2-4IOL
104
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
9 Parameterizing and Configuring
9.1 Parameters_TBEN_S2-4IOL
The module provides 4 byte of module parameters and 16 byte of IO-Link port-parameters for
each IO-Link port.
Word no. Bit no.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Basic
0x00 - - - - - - - - DXP7_
SRO
- DXP5_
SRO
- DXP3_
SRO
- DXP1_
SRO
-
0x01 - - - - - - - - DXP7_
EN DO
- DXP5_
EN DO
- DXP3_
EN DO
- DXP1_
EN DO
-
IO-Link port 1
0x02 Cycle time GSD Activ-
ate
quick
start-
up
Data storage
mode
Operation mode
0x03 - Mapping
PCDO
Mapping
PDIN
Deactivate
diag.
PDIN
invalid
Rev.
0x04…
0x05
- - - - - - - - -
0x06 Vendor ID (MSB) Vendor ID (LSB)
0x07 Device ID Device ID (LSB)
0x08 Device ID (MSB) Device ID
0x09 - - - - - - - - - - - - - - - -
IO-Link port 2
0x0A…
0x11
Assignment similar to IO-Link port 1 (word 0x02…0x09)
IO-Link port 3
0x12…
0x19
Assignment similar to IO-Link port 1 (word 0x02…0x09)
IO-Link port 4
0x1A…
0x21
Assignment similar to IO-Link port 1 (word 0x02…0x09)
The default values are shown in bold type.
Parameter name Value Meaning Description
dec. Hex.
Manual output
reset after
overcurrent
(DXPx_SRO)
0 0x00 Yes
The output switches on automatically after an
overload.
1 0x01 No The output is manually switched-off after an over-
load until a new set-command is given (rise and
fall).
Activate output
Chx (DXPx_ENDO)
0 0x00 Yes
The output at pin 2 is deactivated.
1 0x01 No The output at pin 2 is activated.