Commissioning
Connecting the device to a Siemens PLC in PROFINET
54
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
Example access write – rotate display
The display of the Turck temperature sensors TS-500-LUUPN8X-H1141-... at IO-Link port 1 is ro-
tated. The parameter Measured value update time/rotating/disabling a display in index 55 is
set to 0x05 = 600 ms measured value update time, display rotated by 180°.
Fig.50: Extract from the documentation for TS-500-…