43
Electrical data
perfectMelt 4kg / 8kg
perfectMelt 14kg
Operating voltage
230/400 V, 3L/N/PE
230/400 V, 3L/N/PE
Permissible voltage deviation
+/- 10 %
+/- 10 %
Preliminary fuse max.
3 x 16 A
3 x 16 A
Frequency range
50/60Hz
50/60Hz
Connected load 1 min. (system)
2290 W / 2800 W
6000 W
Connected load 1 min. (system + S + K
external)
10000 W / 11000 W
14000 W
Preliminary fuse tank manifold
4A
4A
Preliminary fuse hose / head
4A
4A
Preliminary fuse L1,L2,L3
6.3A
16A
Preliminary fuse control board
2A
2A
perfectMelt 20kg
perfectMelt 30kg
Operating voltage
230/400 V, 3L/N/PE
230/400 V, 3L/N/PE
Permissible voltage deviation
+/- 10 %
+/- 10 %
Preliminary fuse max.
3 x 16 A
3 x 16 A
Frequency range
50/60Hz
50/60Hz
Connected load 1 min. (system)
9000 W
11000 W
Connected load 1 min. (system + S + K
17000 W
19000 W
Preliminary fuse tank manifold
4A
4A
Preliminary fuse hose / head
4A
4A
Preliminary fuse L1,L2,L3
6.3A
16A
Preliminary fuse control board
2A
2A
The actual power input is determined by the consumers connected to the perfectMelt system.