profile 2 modulator on 300
Modulator on and set the transmission level – 30 dB
Configuration script:
ip address 192.168.0.1 255.255.255.0 1
ip address 192.168.11.1 255.255.255.0 1
ip map 192.168.1.0 255.255.255.0 ml 1 1 0 1
svlan receive 2 1
demodulator lnb power off
demodulator reference off
modulator inversion off
modulator reference off
modulator power off
rf lo 10000000 13050000
profile 2 type au scpc
profile 2 rx 11018170 834
profile 2 tx 14317373 1667 8
profile 2 tlc on 10 0
profile 2 acm on 19 1
profile 2 modulator on 300
profile 2 run
UHP ROUTER SCRIPT-BASED CONFIGURATION PROVIDES A MINIMAL SETUP REQUIRED TO ACTIVATE AND MANAGE A
STATION. BEING AN ADDITIONAL TOOL, IT IS NOT INTENDED TO REPLACE THE STANDARD CONFIGURATION VIA WEB-
INTERFACE.