24/06/08
FR9131
TANGO ERROR CODES
SOFTWARE VERSION FROM V192
ERROR
CODE
INVOLVED COMPONENTS CAUSES CIRCUMTANCES
1 High Level probe Disconnected Permanent
2 High and low level probes Disconnected Permanent
3 Low level probe Disconnected when the high level probe is on
water
Permanent
4 Turntable rotation Wrong positioning
No Rotation or Rotation time too long
During the rotation
5 Overheating safety of coffee boiler Safety thermostat released Permanent
6 Overheating safety of steam boiler Safety thermostat released Permanent
7 Overheating safety of unit 110°C Safety thermostat released Permanent
8 Cleaning cap Cleaning cap removed Permanent
9 Coffee drawer Coffee drawer removed Permanent
10 Descent of Left piston
Safety Time out
No current consumption from the motor<0,5A
during 3 seconds. Motor disconnected or not
supplied
Auto control
Coffee cycle
11 Descent of Right piston
Safety Time out
No current consumption from the motor<0,5A
during 3 seconds. Motor disconnected or not
supplied
Auto control
Coffee cycle
15 Safety of decaffeinated door
Door opened
16 Fuse N°1 cut No 24 Vac power supply to solenoid valves Permanent
17 Fuse N°2 cut No 24 Vac power supply to motors Permanent
18 Fuse N°3 cut No 230 Vac power supply Permanent
20 Fuse N°8 cut No 24 Vdc power supply to piston driver Permanent
21 Fuse N°9 cut No 24 Vdc power supply to turntable driver Permanent
22 Data card which is not adapted to the CPU version
31 Fork sensor No impulse from fork sensor when left piston
goes up
Permanent
32 Down Position sensor of Left piston No signal from Down Position sensor with motor
consumption > 0,5 A and after a safety time of
3 sec.
After 0/1 display of code 36
Auto control
Coffee cycle
33 No Rising of Left piston
No current consumption from the motor<0,5A
during 3 seconds.
Motor disconnected or not supplied
Auto control
Coffee cycle

Table of Contents

Other manuals for Unic Tango

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unic Tango and is the answer not in the manual?

Unic Tango Specifications

General IconGeneral
BrandUnic
ModelTango
CategoryCoffee Maker
LanguageEnglish

Related product manuals