EasyManuals Logo

Universal Robots ur3 Service Manual

Universal Robots ur3
231 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #203 background imageLoading...
Page #203 background image
C740A10 24V voltage is
outside of the
allowed range
Same as C740A
C740A11 48V voltage is
outside of the
allowed range
Same as C740A
C740A12 58V voltage is
outside of the
allowed range
Same as C740A
C740A13 -4V voltage is
outside of the
allowed range
Same as C740A
C740A14 Robot voltage is
outside of the
allowed range
Same as C740A
C740A15 Robot current is
outside of the
allowed range
Same as C740A
C740A17 Inrush protected 48V
voltage is outside of
the allowed range
Same as C740A
C740A20 24V SPI IO voltage 24V voltage IO is outside its
limits
(Below 23,0V above 25,7V)
a) Do a Complete rebooting
sequence
b) Check for loose
connections
c) Check for damages to the
Tool/sensor
d) Update software
e) Contact your local
Universal Robots service
provider for assistance
C740A21 24V SPI IO current 24V current IO is outside its
limits
a) Do a Complete rebooting
sequence
b) Check for loose
connections
c) Check for damages to the
Tool/sensor
d) Update software
e) Contact your local
Universal Robots service
provider for assistance
Service Manual 197 UR3
7.Troubleshooting
Copyright © 2009–2021 by UniversalRobotsA/S. All rights reserved.

Table of Contents

Other manuals for Universal Robots ur3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Universal Robots ur3 and is the answer not in the manual?

Universal Robots ur3 Specifications

General IconGeneral
BrandUniversal Robots
Modelur3
CategoryRobotics
LanguageEnglish

Related product manuals