Current sensor test failed
Sensors reported different
currents when probed
Replace the joint. Defect
Printed circuit board
Power Supply Unit failure
PSU was not able to deliver
48V (In UR10: No 48V)
Check power connection
between power supply and
Safety Control Board
1 PSU active, but we expect 2
(UR10)
PSU was not able to deliver
48V or UR10 flash card in UR5
robot
Check power connection
between power supply and
Safety Control Board and
check that the flash card
and robot match
2 PSUs active, but we expect 1
(UR5)
UR5 flash card in UR10 robot
Check that the flash card
and robot match
Brake test failed during
selftest, check brakepin
Magnetic encoder error
(Absolut encoder)
Invalid decode: Readhead
misalignment, ring damaged
or external magnetic field
present.
Warning: The argument is the
sum of C74 errors
Speed reading is not valid
Warning: The argument is the
sum of C74 errors
System error=malfunction or
inconsistent calibration
detected
Warning: The argument is the
sum of C74 errors
Supply voltage is out of range
Warning: The argument is the
sum of C74 errors
Temperature is out of range
Warning: The argument is the
sum of C74 errors
Signal low =Too far from
magnetic ring
Warning: The argument is the
sum of C74 errors
Signal saturation =Too close to
magnetic ring
Warning: The argument is the
sum of C74 errors
Example: Argument 207 is the
sum of 128,64,8,4,2,1 which
means that all the errors in
connection to argument 1, 2,
4, 8, 64 and 128 have been
reported.
Magnetic encoder error
(Absolut encoder)
Invalid decode: Readhead
misalignment, ring damaged
or external magnetic field
present.
Error: The argument is the sum
of C75 errors
Speed reading is not valid
Error: The argument is the sum
of C75 errors
System error=malfunction or
inconsistent calibration
detected
Error: The argument is the sum
of C75 errors