Whether the DO output status remains after the restart
No action,default value.
Hold: keep the triggering status in the specified time, and back to the previous status, single trigger
Flip: keep the triggering status in the specified time and then flip, periodic trigger
This field is the interval that the system will check for the DI status. The default value is 10 milliseconds
(ms).
3.1.8. Cloud service
Please refer to “USR-M100 Quick Start Guide with AWS IoT” for detail.
Please refer to “USR-M100 Quick Start Guide with PUSR cloud” for detail.
3.1.9. System setup
System setting
This system setting tab includes several system level settings, such as device name, websocket, system log, user name and password.
Most of these settings are optional.
Fig. 30 System settings
Table 18
System settings list
The name of the device, up to 32 characters,can’t be null
Websocket server listen port NO. Range 1-65535
Click the drop-down menu to select websocket mapping direction: UART or Log.
Web server listen port NO. Range 1-65535
The user name of web console and can be modified. up to 16 characters,can’t be NULL
The password of web console and can be modified. up to 16 characters,can’t be NULL
Click the option to enable serial buffer. By default, USR-M100 will empty its serial buffer when a new TCP
connection is established. This means that the TCP application will not receive buffered serial data during
a TCP link breakage. To keep the serial data when there is no TCP connection and send out the buffered