Fig. 14 IP setting of PC
2.8.4. Data transmission test(Step2 and 3)
You can select an operation mode in socket setting page, but for now we use default parameters to test, i.e TCP server. Now
USR-TCP232-Test works as TCP client, you need configure the server IP and port, that is 172.16.14.73:23 of USR-M100 gateway, the IP
address of PC is 172.16.14.15.
In the serial port setting module, you can configure communication parameters for the serial ports RS485, as shown in the figure
below. When configuring a serial network you need to set the following within each device-Baud rate,Parity,Stop bits,Data bits and
keep serial port parameters consistent in the same network. We now configure the COM Settings to operate as required for the M100
devices. Go to the Uart1 Settings tab for confirming values of parameters.
Fig.15 shows an example of parameters setting to test transparent transmission.
Fig. 15 Transparent transmission test