ENGLISH
- 39 -
PARAMETER VALUE DESCRIPTION DEFAULT MEMO
En.SA
ENERGY SAVING function
Thisfunctionisusefulforreducingtheenergyconsumptionofthe
automationdevicewhileinstand-bymode.
Ifthefunctionisenabled,thecontrolunitwillenterENERGYSAVING
modeunderthefollowingconditions:
• 30secondsaftercompletionofanoperationalcycle
• 30secondsafteranopening(ifautomaticclosureisnotenabled)
• 30secondsafterexitingtheprogrammingmenu
InENERGYSAVINGmode,powertotheaccessories,display,ashinglights
andclosureelectromagnetsisdeactivated.
ENERGY SAVING mode is exited:
• Ifanoperationalcycleisactivated
• Ifoneofthekeysonthecontrolunitarepressed
NOTE: during battery powered operation, if the level of charge is
insufcient to activate the automation device (the display shows
Err0), the ENERGY SAVING function is activated automatically in
order to reduce power consumption while awaiting mains power
to be restored.
no
no
Function deactivated
Si
Function activated
t.AP1
Leaf 1 opening time
22.5”
0.0”-5’00
Adjustabletimefrom0secondsto5minutes
t.AP2
Leaf 2 opening time
22.5”
0.0”-5’00
Adjustabletimefrom0secondsto5minutes.
WARNING: if motor 2 is not connected, this time must be set to
zero
t.APP
Partial opening time (pedestrian access)
6.0”
0.0”-1’00
When the control unit receives a Start Pedestrian command, it will open
leaf1only,forashortertime.Maxallowedtimetobesetupist.AP1
t.Ch1
Leaf 1 closing time
23.5”
0.0”-5’00
Temporegolabileda0secondia5minuti
NOTA:Perevitarechel’antanonsichiudacompletamente,èconsigliabile
impostareuntempopiùlungodiquellodiaperturat.AP1
t.Ch2
Tempo di chiusura anta 2
23.5”
0.0”-5’00
Adjustabletimefrom0secondsto5minutes.
NOTE:Toavoidthatthedoordoesnotclosecompletely,werecommend
tosetupalongertimethant.AP2openingtime.
t.ChP
Partial closing time (pedestrian access)
7.0”
0.0” - 2’00
When the control unit receives a Start Pedestrian command, it will use this
timetoclosethegate.Maxallowedtimetobesetupist.Ch1.
NOTE:Toavoidthatthedoordoesnotclosecompletely,werecommend
tosetupalongertimethant.APPopeningtime
t.C2P
Leaf 2 closing time during pedestrian cycle
no
0.5” - 5.0”
Duringapartialopeningcycle(pedestrianaccess)leaf2maymoveslightly
becauseofthewindoritsownweight;inthiscaseatclosingtimeleaf1
couldhitleaf2andthegatewouldremainnotperfectlyclosed.
Toavoidthis,inthelastsecondsofthecyclealightclosingforceisapplied
toleaf2too.
no
Function deactivated