- 40 -
PARAMETER VALUE DESCRIPTION DEFAULT MEMO
r.AP
Opening door delay
1.0”
0.0” - 1’00
Duringtheopeningphase,leaf1muststartmovingbeforeleaf2,toavoid
thatbothdoorsmaycollide.
Leaf2openingwillbedelayedforthesetuptime
r.Ch
Closing door delay
3.0”
0.0” - 1’00
Duringtheclosingphase,leaf1muststartmovingafterleaf2,toavoid
thatbothdoorsmaycollide.
Leaf1closingwillbedelayedforthesetuptime
t.SEr
Lock time
2.0”
0.5”- 1’00
Beforetheopeningphasebegins,thecontrolunitwillenergizetheelectric
lockinordertoreleaseitandenablethegatemotion.t.SEr time will x
theenergizingtime.
m WARNING: in case the gate has no electric lock, set the value
no
no
Function deactivated
SEr.S
Silent Locking Mode
Si
Si
Function activated
no
Function deactivated
t.ASE
Lock advance time
1.0”
0.0”- 1’00
Whiletheelectriclockisenergized,thegatewillstaystandstillfort.ASE
time, to make its release easier.
In case t.ASE is lower than t.SEr,thelockenergizingwillgoonwhile
thedoorswillstartmoving.
mWARNING:incasethegatehasnoelectriclock,setthevalue0.0”
t.inv
Backlash time
no
0.5” - 1’00
Itcouldbeusefultogiveaclosingcommandtomotors,tohelpthe
electric lock release. The control unit controls the motors in reduced power
inclosingdirectionforthesetuptime
no
Function deactivated
t.PrE
Pre-blinking time
1.0”
0.5” - 1’00
Beforeanygatemovement,blinkerwillbeactivatedfort.PrE time, to
warnabouttheincomingmotion
no
Function deactivated
Pot1
Motor 1 power
100
30 - 100
Thedisplayedvalueisthepercentageofmax.motorpower
Pot2
Motor 2 power
100
30 - 100
Thedisplayedvalueisthepercentageofmax.motorpower
Po.r1
Power motor 1 during slow-down phase
50
0 - 70
Thedisplayedvalueisthepercentageofmax.motorpower
Po.r2
Power motor 2 during slow-down phase
50
0 - 70
Thedisplayedvalueisthepercentageofmax.motorpower